• Liberty 1000
  • Type:

    VRLA

  • Liberty 1000
  • Capacity:

    100 - 600 Amp-Hours

  • c&d Technologies Battery
  • Design Life:

    10 Years

  • cd Technologies Battery
  • Operating Environment:

    Indoor
    Outdoor Controlled

Refer to product data sheet for more information.

cd-Techno-Liberty 1000

Features & Benefits

  • Advanced, computer-controlled thermal cover-to-jar weld for greater reliability and consistency
  • Automated, state-of-the-art, cast-on strap process ensures consistent, high-quality, low electrical-resistance welds
  • Through-the-partition intercell connection shortens current paths and increases performance
  • Copper-to-copper connections minimize resistance, especially at high rates, and shorten maintenance time by reducing the need for retorquing connections
  • Patented and time-tested C&D post seal design with secondary epoxy seal to increase integrity for leak-free operation and superior reliability
  • Two-fold vent system, comprised of a low-pressure safety valve with flash arrester, minimizes bulging and prevents flashback explosion from external ignition source
  • Thick radial grid design improves current carrying capacity and performance resulting in long float life
  • Fully automated vacuum and filling operation results in uniform acid volume distribution and consistent float voltage
  • Non-spillable designation for lower shipping cost
  • High-impact resistant PVC container and cover provide excellent water vapor retention, preventing dry out and oxygen infiltration
    100 percent of cells tested for conductance, voltage and capacity
  • Tested in accordance with Bellcore TR-NWT-000766 specifications
  • 100 percent of cells tested to 95 percent capacity at the 8 hour rate to 1.75 VPC

Proprietary Technologies

  1. AGM Glass Mat Technology

Certifications

  1. UL-Recognized Component
  2. Made in the USA
  3. Recyclable
  • 01.

    Customer Premise

  • 02.

    Broadband

  • 03.

    Wireless

  • 04.

    PBX

  • 05.

    Repeaters

  • 06.

    Fixed Wireline

  • 07.

    Outside Plants

  • 08.

    Underground Battery Vaults

  • 09.

    Electric Utility

  • 10.

    Railway Signals

  • 11.

    Emergency Systems

  • 12.

    Manufacturing Facilities

  • 13.

    Assembly Lines

  • 14.

    Process Controls

  • 15.

    Petrochemical processing plants

  • 16.

    Pipelines

  • 17.

    Data Centers

  • 18.

    Network Operations Centers

  • 19.

    Industrial Process Control Facilities

  • 20.

    Semiconductor Manufacturing

  • 21.

    Banks & Financial Markets

  • 22.

    Power Generation Plants

  • 23.

    Hospital & Testing Laboratories

  • 24.

    Emergency 911 response centers